Introduction
Commissioned over a century ago, the City of Montreal’s water supply system has been expanded and repaired over time. By 2026, much of its infrastructure has aged, creating a significant need for increased maintenance. The system features approximately 6,000 valves, including butterfly models. These valves are operated by an actuator – a gear reducer that amplifies the technician’s rotational force to turn the valve disc.
Over time, various actuator models from different manufacturers were integrated into the network. When one breaks down, technicians attempt to repair it, when possible, using original parts. However, these parts have long delivery times, are expensive, and may be unavailable – especially when manufacturers have gone out of business. The City must then resort to makeshift repair solutions or, in the most problematic cases, replace the entire piece of equipment. These situations prolong response times, increase costs, and increase the environmental footprint when equipment is replaced prematurely instead of being repaired.
To address this issue, the City of Montreal’s Water Department sought assistance from ÉTS to develop a universal actuator for butterfly valves ranging from 16 to 48 inches. Standardized and fully repairable, the actuator is designed to simplify maintenance and reduce costs by prioritizing repair over replacement. This project was carried out as part of an internship followed by a research assistant contract under the supervision of a professor in the Department of Mechanical Engineering.
This article presents the design process for the first series of this actuator, from failure analysis of existing models to the creation of a functional prototype, including its sizing, tribological analysis, and eco-design of its gear.
Analysis of existing actuators
Before designing a new actuator, we needed to understand why older models were failing. The study was based on maintenance reports, inspections of damaged parts, and technical experience.
There are three types of mechanisms in the system (Figure 1). The most common is the worm screw actuator – a meshed worm screw with a toothed ring mounted on the output shaft. The Link & Lever and Slotted Lever actuators, however, use a nut that moves along a threaded rod to drive a lever.
A failure analysis revealed five distinct categories (Figure 2). Two of these – external corrosion and input shaft swelling – affect all mechanisms, as most actuators are installed in damp underground chambers exposed to freezing winter temperatures and salt. The other three – overloading, seizure, and wear – are more dependent on design. Overloading occurs when the applied force exceeds the mechanism’s structural limit, either because it is seized or because the technician pushes against the mechanical stop. The latter often results from operating in the wrong direction because some valves in the system do not comply with the standard that specifies the opening direction.
The worm screw actuator was selected as the design basis. Although it is less efficient than the other two mechanisms, it is more robust, less complex, and self-locking. It holds the valve in position without external force, preventing any movement from water pressure or vibration. However, the observed failures indicate that its design needs improvement.
Design
The project was divided into four actuator ranges with the same architecture, because a single model could not cover the entire 16- to 48-inch range. Indeed, the torque required to operate a 48-inch valve is nearly 14 times greater than for a 16-inch valve. Only the 16- to 18-inch range – nearly half of the valves surveyed (Figure 3) – is being developed as part of this project.
For this series, the torque applied to the square drive passes through two reduction stages (Figure 4). A spur gear with a 3:1 ratio drives the worm gear, which rotates the toothed sector at a ratio of 72:1. It takes 54 turns to open or close the valve.
The design addresses the failures observed. To prevent overloading, a safety mechanism (fail-safe) is built into the actuator input. A shear pin connects the square drive to the input shaft. Calibrated to shear before the shafts or gear teeth fail, it is the only part that needs replacement in the event of an overload. To prevent operational direction errors, the housing is designed symmetrically. The input shaft can be mounted on either side, ensuring the mechanism always rotates in the standard direction, using any valve. The unused side is sealed with a blanking plate (Figure 4).
To prevent breakage from corrosion and swelling, the exposed input shaft is made of stainless steel. A deflector plate, installed at a later date, will protect the housing from water and debris.
Finally, the actuator must adapt to the system’s different valves. An interchangeable adapter plate secures it to the valve flange, and the toothed section’s bore is machined to match the valve shaft diameter and key type. The bearings, pin, and hardware are standard components, and the City has drawings for all parts. Consequently, each part can be replaced or refurbished without relying on a manufacturer.
The components are sized for the most common size in the product line – an 18-inch valve – with a 25% torque allowance as specified by AWWA C504, the standard governing butterfly valves in drinking water systems. The gears are analyzed for bending and contact stress; the shafts are analyzed for fatigue. The diameter selected for each shaft is a standard bearing size immediately above the calculated minimum. These calculations are then used to model the actuator (Figure 5).
Tribology
Observed seizure and wear in the existing actuators depend on component contact and proper lubrication. The tribological analysis first verifies whether the gears and bearings can withstand the torque that could shear the pin, which is approximately 1.55 times the rated torque.
For the straight-toothed stainless steel gear, Hertz’s theory indicates a shear stress of 294 MPa, which is below the allowable limit of 440 MPa. The contact between the steel screw and the bronze ring gear is more delicate. A simplified model predicts plastic deformation of the bronze, but ISO 14521, which includes the thread wrapping around the teeth, reduces the shear stress to 89 MPa, compared to a limit of 155 MPa. The softer bronze also acts as a sacrificial part, by concentrating wear on the toothed section rather than on the screw. Plain sintered bronze bearings remain well below their limit.
At 10 revolutions per minute, an adequate oil film does not form between the surfaces, which can lead to seizure. Therefore, a thick, complex lithium grease with extreme-pressure additives is preferred. It resists water washout and remains effective down to -35 °C, which covers Montreal winters.
Eco-design
The gear section is made of bronze, an expensive alloy with a significant environmental impact in its production. In its first version, it was entirely machined from a solid block. The finished part, weighing about 11 kg, required nearly 105 kg of raw bronze, with more than 93 kg ending up as chips.
The second version divides the part into two sections (Figure 6). Only a 110-degree toothed arc is made of bronze, essential for contact with the screw. It is screwed onto a stainless steel hub, which connects it to the valve shaft. Since three arcs correspond to one full revolution, a single wheel – machined and then cut – provides the toothed sectors for three actuators. Thus, the quantity of raw bronze used per actuator is reduced to about 16 kg.
A life cycle assessment, from raw material extraction to part manufacturing, compares the two versions (Figure 7). The second version reduces environmental impact in all studied categories: by 75.9% for ecosystem quality, 70.9% for human health, 57.1% for resources, and 29.5% for climate change. The latter is more modest because stainless steel production remains energy-intensive.
Prototype
Two prototypes were produced. The first, made of plastic and 3D-printed at ½ scale (Figure 8), was used to verify parts assembly and overall dimensions, and to correct any identified defects before machining.
The second is a functional prototype intended for operational testing (Figure 9). It incorporates the first version of the toothed section, as the dual-material version was developed in parallel. The tests, currently underway, follow a pre-established protocol. After a dry run to verify the meshing range, the actuator is tested unloaded, then under load on a test bench equipped with a slightly oversized 24-inch valve (Figure 10). A final disassembly will be carried out to examine wear on the parts and propose improvements.
Conclusion
This project led to the design of the first line of universal actuators for butterfly valves in the City of Montreal’s water supply system, from failure analyses to a working prototype. Its built-in safety pin and reversible housing directly address the failures observed in existing models. Using standard components and the City’s proprietary design drawings made it possible to prioritize repair over replacement and to promote simpler, more environmentally friendly, and less costly maintenance.
The ongoing tests are intended to validate actuator performance under actual load conditions. The developed spreadsheet will then be used to size the three other product lines, gradually covering all valves ranging from 16 to 48 inches. In addition, the design will be adapted to meet the mass production requirements of Quebec companies specializing in casting and machining. This project illustrates the benefits of collaboration between the City of Montreal’s Water Department and the École de technologie supérieure to improve the reliability of drinking water supply infrastructure for the benefit of the city’s residents.
Acknowledgments
The authors thank Emmanuel Rollin, Mathieu Haineault, Luc Péloquin, Steve Lachance, Martin Thériault, Alexandre Salvail and Charles Grenier for their contributions to the design, construction, and testing of the first functional prototype of the actuator.